Ravensdale Kellystown Blakestown (North Salt By) and Leixlip ,
CONDITIONALPlanning application 19304862
Kildare - Kildare County Council
Proposed Development
STRATEGIC INFRASTRUCTURE DEVELOPMENT (ABP Decision) 220 kV Gas Insulated Switchgear substation, 2 no. 220 kV underground circuits forming a loop-in/loop-out to the existing Maynooth-Woodland 220 kV Overhead Line and 6 no. 220 kV underground circuits and associated low voltage and communication underground cabling connecting the proposed substation with electricity transformers within the Intel Ireland Facility, and all associated and ancillary site development works.
Application Timeline
Application received
8 Jul 2019
Decision: CONDITIONAL
21 Nov 2019
Grant issued
23 Dec 2019
Decision due
2 Jan 2020
Application Details
- Location
- Ravensdale Kellystown Blakestown (North Salt By) and Leixlip ,
- Applicant
- N/A
- Application Type
- N/A
- Planning Authority
- Kildare County Council
Timeline
- Registration Date
- 8 July 2019Other applications received that week
- Status
- APPLICATION FINALISED
- Decision
- CONDITIONAL
- Decision Date
- 21 November 2019
- Grant Date
- 23 December 2019
- Permission Expires
- 22 December 2024
Location
Planning Applications Nearby
What the council has granted and refused around this site is the best guide to how a similar application will fare.
for an extension to the west side of the existing dwelling. The extension is made up of an additional family room with the inclusion of an ensuite and walk-in wardrobe to the existing downstairs bedroom. The total floor area of the extension consists of 29.59m²
Kellystown , Leixlip , Co. Kildare
additions, alterations and modification to existing/permitted industrial facilities. The proposed development comprises of the following: 1. An extension to plant and equipment associated with FAB 34 located on an existing/permitted concrete slab to the rear of FAB 34. The development also comprises a modification to the proposed Boiler and Chiller Building to facilitate this development reducing its enclosed area from 22,188 square metres to 19,208 square metres. 2. The proposed equipment comprises 9 no. holding and treatment tanks located in a sealed reinforced concrete bund sized 542 square metres approximately together with associated pumps, pipe bridges and equipment. The tanks vary in height from 5 metres to 9 metres approximately. 3. The permitted (ABP Ref. Pl. 09.304672-19 / KCC Reg. Ref. 1991) two storey Boiler and Chiller Building is reduced by 2,980 square metres approximately, including modifications to the existing elevations, relocated escape stairs and miscellaneous layout modifications. The height of the modified facility will match the existing building height at 24.5 metres. 4. The works also include modifications to site works, underground utilities, roof mounted equipment and site lighting and a louvred screen wall approximately 85 metres in length, as an extension to the existing 8.5-metre-high elevational screen located on top of the Boundary wall to the rear of the Boiler and Chiller Building. 5. Erection of 2 no. ground level, illuminated monument signs at the main east and west vehicular entrances to the site from the R148. Both signs are 1.5 metres high and 2.4 metres wide approximately. 6. Illumination (internally) of 1 no. replacement building sign to the south elevation of the IR6 Building. The sign is 1.4 metres high and 3.3 metres wide approximately and is mounted so that the top of the sign is approximately 0.5 metres below for the parapet level of IR6. This application consists of a variation to a previously permitted development for an activity for which a licence under Part IV of the Environmental Protection Agency Act 1992 )as amended by the Protection of the Environment Act, 2003) is required. This is a site to which the Chemicals Act (Control of Major Accident Hazards Involving Dangerous Substances) Regulations 2015 (S.I. 209 of 2015) applies
Collinstown Leixlip , Blakestown Kellystown , Collinstown Industrial Park
for a new chemical tanker storage compound located north of FAB 10. The proposed development consists of a modification and alterations to previously permitted and partly built development under planning application Reg. Ref. 19/1054. The proposed development comprises of the following: (1) Chemical Tanker Storage Compound. A chemical storage compound housing 3 no. parked chemical tanker trailers complete with bunded area, steel canopy and adjacent loading bay with bunded fixed tank (12,000 litres). The chemical tanker storage compound is approximately 220 square metres and the steel canopy is sized 13 metres x 11 metres approximately. (2) Site works. The proposed development includes minor modifications to previously permitted roads and underground utilities, paths, fencing, site lighting, signage and also includes miscellaneous site works. This application consists of a variation to a previously permitted development on an activity for licence under Part IV of the Environment Protection Agency Act 1992 (as amended by the Protection of the Environment Act, 2003) is required. A Natura Impact Statement ("NIS") accompanies this application, and will be available for inspection or purchase at the office of the Planning Authority. This is a site to which the Chemicals Act ( Control of Major Accident Hazards Involving Dangerous Substances) Regulations 2015 (S.I. 209 of 2015) applies
Collinstown Leixlip , Blakestown Kellystown , Collinstown Industrial Park Leixlip
(1) Mound The substantial removal of an existing man made earth and stone mound sized approximately 300 metres x 150 metres and up to approximately 18 metres high and approximately 380,000 metres cubed located directly North of Fab 10 and Fab 14. (2) Yard The construction of a yard area housing site supporting functions, utilities and buildings sized 300 metres x 150 metres approximately on the site of the removed mound area, as further described hereunder. (i) Waste Water A waste water tank sized 51 metres by 33 metres and 12 metres high and a yard housing tanks and equipment. (ii) Balance Tank A site waste water (below grade) balance tank sized 35 metres x 25 metres. (iii) Air Separation Unit An Air Separation Unit (ASU) compound and associated 4 no. towers 43 metres high, cooling towers, associated equipment and a single storey compressor building sized 450 square metres and circa 25 metres high, and 2 no. single storey Electrical buildings sized 120 square metres gross and 7 metres high. (iv) Electrical Buildings 4 no. Electrical buildings, all elevated single storey buildings with a gross area of 648 square metres and 6 metres high. (v) Storage Tanks A yard area housing bulk storage tanks for liquid oxygen, waste solvent storage and hydrogen and their associated tanker unloading. (vi) Waste Water Holding Tanks A series of modular waste water holding tanks and associated equipment located in yards with connecting pipebridges. The proposed tanks range from 5 metres high to 20 metres high. (vii) Tanker and Truck Staging Yards A tanker and truck holding and staging yard sized circa 80 x 40 metres located to the North of the proposed development. (3)Site Works The proposed development includes linking pipe-bridges to the Fab 10, Fab 14 and Fab 24 support buildings, site development works and a surface water attenuation tank, site utilities, site lighting, separation walls, roads, landscaping and all associated site works. This application consists of a variation to a previously permitted development for an activity for which a licence under Part IV of the Environmental Protection Agency Act 1992 (as amended by the Protection of the Environment Act 2003) is required. An Environmental Impact Assessment Report (EIAR) and a Natura Impact Statement (NIS) accompany this application. This is a site to which the Chemicals Act (Control of Major Accident Hazards Involving Dangerous Substances) Regulations 2015 (S.I. 209 of 2015) applies. Revised by SFI
Collinstown , Leixlip , Co. Kildare
for additions, replacements and modifications to existing industrial facilities located at Collinstown, Leixlip, Blakestown, Kellystown, Collinstown Industrial Park, Leixlip, Co. Kildare. The proposed development consisting of additions and modifications to the previously permitted (KCC Reg. Ref. 19/1054) and partially completed development, which incorporates a new Utility Building. The proposed development also includes other buildings, plant and equipment to be located North of Fab 10 and Fab 24. The proposed development is comprised of the following: (1) A Utility Building sized approximately 561 square metres approximately 10 metres high, housing plant and equipment and also including adjacent yard-based plant and equipment, consisting of a 16-metre-high storage tank approximately 3 metres in diameter, housing for electrical controls and external pipework. Also including a 4-metre-high acoustic screen, additional pipe bridges, all located north of Fab 10. (2) An elevated single-storey extension to the existing electrical building located north-west of Fab 10 sized 60 square metres approximately and 8.5 metres high approximately and a local connecting pipe bridge. (3) A building ancillary to the Fab 10 Reverse Osmosis Deionised Water (RODI) building located north of Fab 10 sized 75 square metres approximately and 7.9 metres high approximately including an Air Handling Unit, approximately 3.1 metre high located on the roof. (4) 2 no. tanks, each sized approximately 20.4 metres high and approximately 4.6 metres in diameter. 1no. located in the yard to the north of Fab 10 and 1no. located in the yard north of Fab 24. (5) The proposed development also includes minor modifications to site works, access road, underground surface water retention features, additional underground utilities, site lighting, pipe bridges, roof mounted equipment and internal roadworks. The application relates to a modification to a development which comprises or is for the purpose of an activity requiring an industrial emissions license under Part IV of the Environmental Protection Agency Act 1992 (as amended by the Protection of the Environment Act, 2003) is required. This application relates to development consisting of the modifications to an establishment within the meaning of the Major Accidents Directive (i.e. a COMAH / Seveso site).
Intel Ireland Limited , Collinstown Industrial Park , Leixlip
for a single storey dwelling, domestic garage, installation of new proprietary waste water treatment system and polishing filter together with all associated site works. The development also includes new domestic entrance with access via an existing shared entrance and private roadway
Sion , Leixlip , Co. Kildare.
modifications to existing Fab 10, 14 and 24 facilities and yards, comprising: - A 3 storey support building housing plant and equipment, sized 540 square meters and 18.5 meters high, located to the rear of Fab 10, and a sunken bund area with a roof canopy 6 meters high, housing plant and tanks in the yard area to the rear of Fab 10 sized 270 square meters and 7 meters deep and with a pipe bridge and with 2 gound level tanks. – An external equipment lift shaft sized 200 square meters and 18 meters high and a single storey chemical room extension for F10 sized 210 square meters and 9 meters high both located to the west of Fab 10. – A single storey gas cylinder storage extension sized 168 square meters and 5 meters high located to the west of Fab 10. – A single storey Water Treatment building extension with an internal mezzanine sized 300 square meters and 9 meters high located to the north of the Fab 10 Water Treatment building and a single storey energy centre extension sized 156 square meters and 9 meters high and a bunded tank enclosure located to the north of the Fab 10 energy centre. – Roof mounted equipment, a 4 meters high acoustic screen and a 4 meters high visual screen and 3 general exhaust stacks, 6.5 meters high above existing parapet located to the rear of the Fab 10 roof. – Building links located between Fab 10 and Fab 14, one elevated link sized 264 square meters, 9 meters high and 5 meters above ground; and the extension of an existing elevated pedestrian link sized 69 square meters, 9 meters high and 5 meters above ground level; and a ground level link sized 138 square meters, 9 meters high both including roof modiciations to existing single storey kitchen server; and an elevated link located between Fab 14 and Fab 24 sized 456 square meters, 9 meters high and 5 meters above ground, all housing plant and equipment. – 2 no. bunded solvent storage tanks and associated truck staging area located to the rear of Fab 14. This application consists of a variation to a previously permitted development for an activity for which a licence under Part IV of the Environmental Protection Agency Act 1992 (as amended) is required and full details of the proposed development and its anticipated environmental impacts will be notified to the Environmental Protection Agency. This is a site to which the Chemicals Act (Control of Major Accident Hazards Involving Dangerous Substances) Regulations 2015 (S.I. 209 of 2015) applies
Collinstown Leixlip Blakestown Kellystown , Collinstown Industrial Park , Leixlip
modifications to the permitted ASU's (Air Separation Units, tank and equipment installations granted as part of the development permitted under An Bord Pleanála Ref. ABP-304672-19 (Kildare County Council Ref. 19/91), including reconfigured site layout of the proposed structures and support plant. The proposed development comprises: Air Separation Units. The proposed development includes positional alterations to the 2no. permitted Air Separation Unit (ASU) compounds, associated towers and compressor buildings. Towers are circa 65 metres high and associated compounds including tanks and equipment are circa 45 metres high and compressor buildings are approximately 20m metres high, all located to the north of the existing Fab 14 building. The ASU compounds also comprise of 2no. compressor buildings each sized 765 square metres approximately and circa 20 metres high with roof mounted plant, equipment and storage and associated 1no. single storey electrical building sized 60 square metres approximately and circa 6 metres high with roof mounted equipment. The proposed development also relates to associated site development works associated equipment housings, yard works and tank bunds, pipe-bridges, and lighting. The application consists of a variation to a previously permitted development for an activity for which a licence under Part IV of the Environmental Protection Agency Act 1992 (as amended by the Protection of the Environment Act, 2003) is required. A "Natura Impact Statement ("NIS") accompanies this application, and will be available for inspection or purchase at the office of the Planning Authority. This is a site to which the Chemicals Act (Control of Major Accident Hazards Involving Dangerous Substances) Regulations 2015 (S.I. 209 of 2015) applies
Collinstown Leixlip , Blakestown Kellystown , Collinstown Industrial Park
the replacement of approximately 120m of existing 2.3m high chainlink perimeter fencing and associated access/emergency gates with new 2.4m green palisade security fencing/gates and all associated site works
Existing Above Ground Natural Gas Installation at , Collinstown , Leixlip
(1) Modular Storage Unit. A Single storey storage unit, sized approximately 7 metres by 12 metres and 6 metre high, located in the Utilities Yard to the north of the existing Fab10 Support Building. (2) FAB10 Waste Tanks. The installation of 3no. new bunded waste storage tanks, 2no. sized approximately 2.5 metres in diameter and 16.5 metres high, located in the Utilities Yard to north of the existing Fab10 Support Building and 1no. sized approximately 3.7metres in diameter and 15 metres high located to the north of the Fab10 Utilities Yard. (3) Process Support Building Extension. The construction of a two-storey extension to the existing Process Support Building (PSB) sized approximately 20 metres by 11 metres and 14 metres high, located to the north east of the existing Fab 24 Process Support Building. (4) FAB24 and FAB14 Waste Tanks. The installation of 3no. additional waste tanks and associated access platforms and stairways, 1no. sized approximately 9 metres by 10 metres and 7 metres high, located in the Utilities Yard to the north of the existing FAB24 Manufacturing Building and 1no. sized approximately 3 metres high located to the south of existing FAB14 Process Building and 1 no. sized approximately 4.25 metres in diameter and 16 metres high, located to the south of existing FAB14 process Building.(5) Site Works. The proposed development includes linking pipe-bridges to the Fab10 and Fab14 support buildings, site development works, site utilities, site lighting, separation walls, road alterations, landscaping and all associated site works. This application consists of a variation to a previously permitted development for an activity for which a licence under Part IV of the Environmental Protection Agency Act 1992 (as amended by the Protection of the Environment Act, 2003) is required. A Natura Impact Statement ("NIS") accompanies this application for inspection or purchase at the office of the Planning Authority. This is a site to which the Chemical Act (Control of Major Accident Hazards Involving Dangerous Substances) Regulations 2015 (S.I.209 of 2015) applies
Collinstown Leixlip , Blakestown Kellystown , Collinstown Industrial Park
Planning a project of your own?
Find out in two minutes whether you need planning permission. It's free, and based on the exempted development regulations.
Do I Need Permission?